Cover image for "Embodied Carbon in Buildings: How to Measure It and What the Rules Say in 2026"

Embodied Carbon in Buildings: How to Measure It and What the Rules Say in 2026

Embodied carbon is the share of a building’s emissions locked in before anyone moves in. Here is how it is measured, what the EU now requires, where UK policy stands and how to reduce it.

Embodied carbon in buildings is the greenhouse gas emitted to make, transport, install, maintain, replace and finally demolish a building’s materials. It excludes the energy used to run the building. Most of it is emitted before the building opens, so design and procurement decisions fix it early. It cannot be reduced later through efficiency.

As buildings use less operational energy and the grid decarbonises, embodied carbon becomes a larger share of a building’s whole-life impact. Clients, lenders and planning authorities increasingly ask for it. This post explains how it is defined, how it is measured, what the EU now requires, where UK policy stands in October 2026, and how to cut it. For the operational side of the story, see https://auditmycarbon.com/what-is-a-net-zero-building/.

What counts as embodied carbon in a building?

Whole-life carbon assessments follow the life-cycle modules in EN 15978, the European standard for assessing the environmental performance of buildings.

Six life-cycle stages of a building under EN 15978, from product stage A1-A3 through end of life C1-C4 and module D

Embodied carbon covers every module except operational energy (B6) and operational water (B7):

  • Upfront carbon (A1–A5): material extraction, manufacturing, transport to site and construction works. This is emitted before practical completion.
  • In-use embodied carbon (B1–B5): maintenance, repair and replacement over the building’s life, such as new roof membranes, façades or building services plant.
  • End-of-life carbon (C1–C4): demolition, transport, waste processing and disposal.

Module D records potential benefits and loads beyond the life cycle, such as reusing steel. It is reported separately and should never be netted off the main result.

Our guide to life cycle assessment methodology stages explains the LCA principles behind these modules.

How is embodied carbon measured?

An assessment multiplies quantities of materials and activities by emission factors, module by module.

  1. Take quantities from the cost plan, bill of quantities or BIM model: tonnes of concrete, steel, brick, glass, insulation and so on.
  2. Choose emission factors. Use product-specific Environmental Product Declarations (EPDs) where you have them, and generic database values where you do not.
  3. Add transport and site activities (A4–A5): delivery distances, site fuel and electricity, and construction waste.
  4. Model the use stage and end of life with replacement cycles and end-of-life scenarios over a stated reference study period.
  5. Report the results in kgCO2e and per m² of floor area, by module, with assumptions stated.

In the UK, most practitioners follow the RICS professional standard Whole life carbon assessment for the built environment (2nd edition), which took effect on 1 July 2024. It applies EN 15978 to UK practice and sets reporting rules.

The data you have changes over a project. At concept stage, generic factors and rough quantities are normal. By technical design, you should be using EPDs for the high-impact elements: frame, substructure, envelope and building services.

What does a worked example look like?

Here is a simplified product-stage (A1–A3) estimate for a hypothetical 2,000 m² office. The quantities are illustrative. The factors come from the DESNZ 2026 conversion factors, material use, primary material production, in kgCO2e per tonne. For primary materials, those factors cover extraction, primary processing, manufacture and transport to the point of sale.

Material Quantity (t) DESNZ 2026 factor (kgCO2e/t) Emissions (tCO2e)
Concrete 2,400 118.80 285.13
Metals 180 3,821.95 687.95
Bricks 300 241.80 72.54
Plasterboard 40 120.05 4.80
Insulation 15 1,861.80 27.93
Total 1,078.35

Per square metre: 1,078.35 tCO2e × 1,000 ÷ 2,000 m² = 539 kgCO2e/m² for these five materials at the product stage only.

Three lessons from this simple sum:

  • Metals dominate. 180 t of metal produces more than twice the emissions of 2,400 t of concrete, so frame design and steel specification matter most here.
  • Mass is not impact. Insulation is the smallest quantity by weight but outweighs plasterboard almost sixfold.
  • Generic factors are a starting point. DESNZ material factors are national averages for Scope 3 reporting. A real assessment should replace them with EPDs for the specific products, which can be much higher or lower.

Treat this as a screening method, not a substitute for a full assessment to EN 15978 and the RICS standard.

What do the rules require in 2026?

European Union

The recast Energy Performance of Buildings Directive, Directive (EU) 2024/1275, makes life-cycle carbon a legal disclosure. Article 7(2) requires Member States to ensure the life-cycle global warming potential (GWP) of new buildings is calculated and disclosed in the energy performance certificate:

  • from 1 January 2028, for new buildings with a useful floor area above 1,000 m²
  • from 1 January 2030, for all new buildings

Annex III requires the result as kgCO2e per m² of useful floor area for each life-cycle stage, over a 50-year reference study period, calculated in line with EN 15978. Article 7(5) requires each Member State to publish a roadmap by 1 January 2027 for introducing limit values on total life-cycle GWP for new buildings, with targets from 2030. The general transposition deadline was 29 May 2026.

This matters to UK firms that design, build or own property in EU Member States, and to suppliers whose EPDs feed those calculations.

United Kingdom

As of October 2026, England has no national legal requirement to measure or cap embodied carbon in new buildings. Building Regulations deal with operational energy.

In July 2025, MHCLG published research by AECOM on the practical, technical and economic impacts of measuring and reducing embodied carbon in new buildings. The cover note states that publication “does not indicate any specific future action” and that the government is considering whether intervention would be appropriate.

Requirements still arise in other ways:

  • Planning: the London Plan requires whole life-cycle carbon assessments for applications referable to the Mayor, and some local plans set their own policies.
  • Public infrastructure: in March 2026 the National Infrastructure and Service Transformation Authority (NISTA) published a Whole Life Carbon Management handbook, written to support project outcomes in line with PAS 2080:2023.
  • Clients and investors: many briefs, green leases and green loan frameworks now ask for upfront carbon figures.

How can you reduce embodied carbon in buildings?

The biggest savings come earliest, when options are still open:

  1. Build less. Retaining and refurbishing an existing structure avoids most product-stage emissions. Test retention before demolition.
  2. Use less material. Efficient structural grids, shorter spans and right-sized foundations cut tonnages directly.
  3. Specify lower-carbon products. Compare EPDs for cement replacement in concrete, high recycled-content steel and lower-impact insulation.
  4. Design for long life and disassembly. Fewer replacements in B4 and recoverable components at end of life.
  5. Cut site emissions. Grid connections instead of diesel generators, efficient plant and less waste reduce A5.
  6. Set a target and track it from concept to completion, so later value engineering does not quietly push numbers up.

Material choices link directly to heavy industry. Our article on industrial decarbonisation explains how cement and steel producers are cutting their own emissions.

How does embodied carbon fit into a company carbon footprint?

For most organisations, embodied carbon sits in Scope 3. A developer or owner buying a new building records it mainly in Category 2 (capital goods). A contractor records materials it buys in Category 1 (purchased goods and services). Fuel burned in its own site plant is Scope 1. An occupier leasing space usually reports operational energy and treats fit-out works as purchases.

That is why one building can appear in several companies’ footprints. Each party reports its own share from its own boundary. It is also why a fit-out or new-build project can cause a one-year spike in Scope 3 that needs explaining in your reporting narrative.

To see how a building project compares with the rest of your footprint, start with our business carbon footprint calculator. If you are planning a new building, refurbishment or major fit-out and want an embodied carbon screen before design decisions are fixed, book a carbon audit.

FAQ

What is the difference between embodied and operational carbon?

Operational carbon comes from energy and water used to run a building (modules B6 and B7). Embodied carbon covers everything else: materials, construction, maintenance, replacement and end of life. Together they make up whole-life carbon.

Is upfront carbon the same as embodied carbon?

No. Upfront carbon is the part of embodied carbon emitted before completion, modules A1 to A5. Embodied carbon also includes in-use replacements (B1 to B5) and end-of-life stages (C1 to C4).

Is an embodied carbon assessment mandatory in the UK?

There is no national legal requirement in England as of October 2026. Requirements can still come from planning policy, such as the London Plan, or from public-sector and private client briefs.

Can I use DESNZ conversion factors for an embodied carbon assessment?

They are suitable for early screening and Scope 3 reporting, as shown in our example. A formal assessment to EN 15978 and the RICS standard should use product-specific EPDs wherever they exist.

When does the EU require life-cycle GWP disclosure?

Under Directive (EU) 2024/1275, from 1 January 2028 for new buildings above 1,000 m² of useful floor area. From 1 January 2030 it applies to all new buildings, and the result goes in the energy performance certificate.

Sources